Alarm Watches and Pill Timers. |
|
|
Display
Modes: The watch has four display modes: normal time and calendar,
medication alarmbank , medical databank, and watch activate switch. To
change from one display mode to another, press the MODE button
repeatedly.
Do this now.
When
the TIME mode is selected, the watch will display current time in
HOURS,
MINUTES, and SECONDS. The calendar will display DAY, MONTH, and DATE.
How to Set Time and Date:
1) Select TIME mode by pressing the MODE button (repeatedly if necessary). When your watch is in the TIME mode, press and hold the ADJUST button for two seconds. This will cause the Hour to begin flashing.
2) Use the FORWARD or REVERSE buttons to select the Hour. PLEASE MIND THE "A" OR THE "P" IN THE LOWER LEFT CORNER INDICATING AM AND PM. Press MODE button to record the Hour and move on to Minutes.
3) Press the FORWARD or REVERSE buttons to select the Minutes. Press MODE button to record the Minutes, and move on to Seconds.
4) Repeat these steps to set the seconds, year, month, and date. The watch automatically calculates the day of week.
5)
Press
ADJUST at any time to accept your changes and return to TIME mode.
The
CADEX watch has 12 daily alarms available. They are numbered 1 through
12. This numbering is for reference only. Alarm number 1 does not have
to be the first alarm of the day and so on.
The watch allows up to 36 characters to be recorded in each Medication Alarm. If you take multiple medications at a given time, we recommend you abbreviate if necessary. You may also want to set alarms to remind you to perform a certain test daily, or to perform a specific exercise.
Tips: If you are normally away from home during the day, we recommend you make an alarm for the early part of the day that says "SETUP MEDS". You should set this alarm for the time that you are normally doing your morning routine (breakfast, coffee, etc.), this will remind you to get your medications together and into your pocket or purse so you will not forget them.
How to Set Medication Alarms:
1) Select the ALARM mode by pressing the MODE button (repeatedly if necessary). When the watch displays "ALARMBANK", you are in the correct mode. Press the FORWARD or REVERSE buttons to select the alarm you wish to view or set.
2) When you are at the alarm you wish to set, press the ADJUST button for two seconds, this will cause the Alarm Number (AL 1, AL 2, AL 3 É) to begin flashing. Press FORWARD or REVERSE to toggle the Alarm Indicator ((*)) on and off. When the Alarm indicator is on the screen, it means the alarm is enabled. The absence of this symbol indicates the alarm is disabled. Make your selection, and press MODE to move on to alarm Hour.
3) Press the FORWARD or REVERSE buttons to select the Hour. Press MODE to move on to Minutes.
4) Press the FORWARD or REVERSE buttons to select the Minutes. Press MODE to move on to Medication Name.
5) Press the FORWARD or REVERSE buttons to select the first letter of the Medication Name. TIP: PRESSING AND HOLDING THE FORWARD OR REVERSE BUTTONS WILL ALLOW THE CHARACTERS TO INCREMENT QUICKLY.
6) Press MODE to move on to the next character in the Medication Name. TIP: PRESSING AND HOLDING THE MODE BUTTON WILL ALLOW THE PREVIOUS CHARACTERS TO BE ACCESSED AGAIN .
7)
Repeat
these steps as many times as necessary to spell out the Medication
Name.
Press ADJUST at any time to save your changes and return to ALARMBANK
mode.
Your setting will scroll across the screen. Press MODE to return to
time,
or press FORWARD or REVERSE to access more alarms.
The
CADEX watch is capable of recording the following pieces of information
at
your option:
1) Select the DATABANK mode by pressing the MODE button (repeatedly if necessary). When the watch displays "DATABANK", you are in the correct mode. Press the FORWARD or REVERSE buttons to select the Data Item you wish to view or set.
2) When you are at the Data Item you wish to set, press the ADJUST button for two seconds. The first letter of the Data Item will begin flashing. Press the FORWARD or REVERSE buttons to select the first letter of the Data Item. TIP: PRESSING AND HOLDING THE FORWARD OR REVERSE BUTTONS WILL ALLOW THE CHARACTERS TO INCREMENT QUICKLY.
3) Press MODE to move on to the next character for this Data Item. TIP: PRESSING AND HOLDING THE MODE BUTTON WILL ALLOW THE PREVIOUS CHARACTERS TO BE ACCESSED AGAIN .
4)
Repeat
these steps as many times as necessary to spell out the Data Item.
Press
ADJUST at any time to save your changes and return to DATABANK mode.
Press
MODE to return to time or press FORWARD or REVERSE to access the next
Data
Item.
This
watch contains an electronic master switch that will turn all alarms on
or off. This switch can be used to save battery life if the watch is
not
to be used for an extended length of time, or to quiet the watch during
sensitive occasions.
How to set the Master Switch:
1)
Select
the ACTIVATE mode by pressing the MODE button (repeatedly if
necessary).
When the watch displays "ACTIVATE" you are in the correct mode. Press
the
FORWARD or REVERSE buttons to toggle between "YES" and "NO". NOTE:
"YES"
MEANS ALL OF THE INDIVIDUALY ENABLED ALARMS WILL FUNCTION. "NO" MEANS
ALL
OF THE INDIVIDUALLY ENABLED ALARMS WILL NOT FUNCTION, HOWEVER THEY ARE
ALL RETAINED IN MEMORY. WHENEVER YOU TAKE YOUR WATCH OUT OF STORAGE, BE
SURE TO SET THE ACTIVATE SWITCH TO "YES".
If there are multiple alarms existing in REMINDER MODE, each alarm entry will scroll across the face of the watch in turn. A medication alarm may be dumped from the REMINDER MODE by pressing either of the FORWARD or REVERSE buttons while that medication alarm is on the display. Multiple alarms in reminder mode may cause the watch to do its reminder beep more often than every three minutes.
The other way you can erase information is to press and hold all four buttons until the watch display goes blank. Release the buttons and the watch will beep. This method will erase ALL information from your watch, and you will need to reprogram your medications and alert information.
Read This Important Information
| IF YOU CURRENTLY WEAR A MEDICAL
ALERT IDENTIFICATION
BRACELET OR NECKLACE, YOU SHOULD CONTINUE TO WEAR IT. THIS WATCH IS AN
ELECTRONIC DEVICE. IF THE WATCHÕS ELECTRONIC PARTS OR BATTERY
FAIL,
NO ONE WILL BE ABLE TO ACCESS YOUR IMPORTANT MEDICAL INFORMATION. DO
NOT
TAKE THIS RISK.
Battery: At the first sign of low power (dim display), have the battery replaced at your local jeweler, department store, or drug store. The battery that comes installed in this watch when you purchase it is for factory test purposes, so the battery will probably not provide normal service life. When replacing the battery use CR2032 or equivalent. CAUTION: DEAD BATTERY, REPLACEMENT OF BATTERY, MALFUNCTION, OR REPAIRS WILL CAUSE ALL DATA STORED IN THE MEMORY OF THE WATCH TO BE DELETED. IT IS RECOMMENDED THAT YOU KEEP SEPARATE WRITTEN COPIES OF ALL IMPORTANT DATA. IN NO EVENT WILL CADEX BE LIABLE FOR LOSS OF DATA OR DAMAGES ARISING OUT OF SUCH LOSS. Water Resistance: This watch is water resistant. It will withstand splashes and rain, swimming, bathing, and showering. It will not withstand snorkeling and diving or scuba diving. Do not operate the buttons underwater. Care of Your Watch: Never try to open the case or remove its back cover. Your should have the rubber seal that keeps out water and dust replaced every 2 to 3 years. Should moisture appear inside the watch, have it checked immediately by your dealer or a CADEX distributor. Avoid exposing the watch to temperature extremes. Avoid dropping the watch. Avoid exposing the watch to gasoline, cleaning solvents, adhesive agents, paint, or aerosol sprays. Some watches have silk screened logos on the band. Be careful when cleaning such bands that you do not rub too hard on the logo. |
|
The inner components of this watch are warranted to be free from defects in materials and manufacturerÕs workmanship for one year from the original date of purchase. This warranty does not cover the band, buckle, battery, case, buttons, or crystal. This warranty expressly excludes incidental and consequential damage caused by use, misuse, neglect, accident, unauthorized modification, or any defects resulting from service by anyone other than the manufacturer. During the warranty period, and upon proof of purchase, this watch will be repaired or replaced (with the same or a similar model) at the manufacturer's option. Contact CADEX, PO Box 2286, Ketchum, ID 83340. Phone: 888-726-8805. THE CADEX WATCH IS ONLY A SUPPLEMENT TO ANY MEMORY SYSTEM THAT YOU CURRENTLY USE TO REMIND YOURSELF TO TAKE MEDICATIONS OR PERFORM MEDICAL TASKS. THE USER MAINTAINS FULL RESPONSIBILITY TO ADMINISTER MEDICATIONS OR PERFORM MEDICAL TESTS AT THE APPROPRIATE TIMES. NEITHER THIS WARRANTY NOR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE, SHALL EXTEND BEYOND THE WARRANTY PERIOD. NOCADEX ASSUMES NO RESPONSIBILITY IS ASSUMED FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT WITHOUT LIMITATION, DAMAGES OR INJURIES RESULTING FROM MALFUNCTION OF THE PRODUCT MATHEMATICAL INACCURACY, OR LOSS OF STORED DATA. |